  linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 2 0% to full load. (7)line regulation measured from 1 00vac to 277vac. (8)preset accuracy measured at nor mal load, 120vac input. reference ce en55015 / fcc part15 i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac dimensions(l*w*h) emi withstand voltage ul 60950-1 / tuv en61347-2-13 / cb / pse / kc short circuit protection will restart automatically after the fault condition is removed range:47-63hz, normal 50-60hz 250 power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch model name size 11 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh model no. part no. lcvh-100  240 plcvh1100  240 *(9) module : lcvh-100  240 features output current(a) *(5) rohs compliant lcvh-100  240 nrom. 24 max. min. power factor:>0.98@115vac;>0.95@230vac;@full load dc output voltage (v) 4.2 high operating ambient temp: -30 ~+70 (refer to output dreating curve) ac input 90~305vac safety relative humidity over v, protection pf>0.98 @115vac, pf>0.95@230vac at full load and ra ted output voltage cold start 65a @ 230vac 120%~160% rated output power ; hiccup mode <0.45ma/264vac ac current 10 to +90%, non-cond. short circuit protection over current protection 0.03% / (0-50 , typ) over temp. protection storage temperature -30 to +70 (refer to output dreating curve) -40 to +80 operating temp.*(4) temp. coefficient shut down and latch off o/p voltage , re-power on t o recover protection: ovp / otp / scp / ocp (9)100% production tested. (5)minimum load is not required fo r proper operation . notes (1)all parameters not specially mentioned are measu red 230vac input. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured direc tly at pins/terminals at nom. load, 0.1uf bypass an d 47uf electrolytic, pk-pk @20mhz bandwidth. (4)specified for free-air convecti on cooling. isolation resistance leakage current dimension (l*w*h): 8.2 * 2.83 * 1.52 inch active power factor efficiency(typ @full load) setup,rise time(typ.) inrush current (typ) 1.7a/115vac 0.65a/230vac line regulation (%) *(7) load regulation (%) *(6) preset accuracy (%) *(8) safety: ul / tuv / cb / pse / kc emc: ce / fcc comply with indoor/outdoor waterproof (ip 67) dimension (l*w*h): 208.4 * 72 * 38.55 mm o/p noise (p-p, mv) *(3) 1 input frequency 90% hold up time dc output power input voltage range 25ms at full load 115vac/230vac 90-305vac, 127-431vdc, normal 100-277vac 2000ms,500ms at full load 115vac/230vac 100.8 w www.linkcom.com.tw for more information, please contact with: sales@ linkcom.com.tw
linkcom manufacturing co., ltd power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch model name size model no. part no. lcvh-100  240 plcvh1100  240 reference dimensions derate unit :mm inch www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw


▲Up To Search▲   

 
Price & Availability of LCVH-100X240

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X